Cellocator CR-300

Cellocator CR-300B is an entry-level GPS tracking device for fleet management and vehicle security applications supporting 2G and 3G connectivity. The device features a motion sensor, rechargeable backup battery, and GSM jamming detection algorithms.

Protocol: cellocator Manufacturer: Cellocator Forum discussion
Properties
Connect to Server
connect_to_server
server: Server
Dallas Key 2
dallas2
Dallas 02 code
dallas_key2: Dallas Key
Dallas Key 3
dallas3
Dallas 03 code
dallas_key3: Dallas Key
Immobilizer
immobilizer
Enable Immobilizer activation while there is no Authentication code
imm_enable: Enable Immobilizer
Odometer Unit
odom_unit
GPS odometer base unit
value: Base Unit
Output state change
output
Change one output state at a time
time: Output change time
state: Output ON State
output: Output
vehicle_stop: Require vehicle stop
Request Position
request_pos
Reset Unit
reset
Request SIM ICCID
sim_iccid
Properties
Generic Command
custom_message_type_0
Generic command, message type 0
code: Command code
spec: Command specific data field
data1: Command data field 1
data2: Command data filed 2
Reset device
{"code":2,"data1":2}
Request status from device
{"code":0}
Commence gradual engine stop
{"code":7}
Tracking control with resolution of time events 4
{"code":5,"data1":4}
Programming command
custom_message_type_1
Programming command (message type 1) - allows to configure the device
data: Block data - 16 bytes HEX
block: Block code number
bitmask: Bitmask - 2 bytes HEX
Set maintenance server connection period 2 days
{"data":"00000000000000200000000000000000","block":87,"bitmask":"8000"}
Register Dallas key 2 (iButton code 2) with value 112233445566
{"data":"00000066554433221100000000000000","block":27,"bitmask":"F801"}
Modular Message Request
custom_message_type_9
Modular message request, message type 9
data: Sub-Data
type: Sub-Data type
CAN data request
{"type":2}
Firmware manifest request
{"type":1}
Time and location stamp request
{"type":4}
Output state change
output
Output state change
state: Desired state of output
ordinal: Output ordinal number
Set Output 0 (siren) ON
{"state":true,"ordinal":0}